A Level Chemistry Notes, Chemistry A Level

OCR A 6.3.1 Chromatography: Complete Revision Notes

Chromatography separation experiment with solvent front and separated spots

OCR A Level Chemistry H432, 6.3.1: Chromatography

Specification Points Covered:

  • Principles of separation by chromatography
  • Paper chromatography (plant pigments, amino acids, food dyes)
  • Thin-layer chromatography (TLC)
  • Gas chromatography (GC) and mass spectrometry (GC-MS)
  • High-performance liquid chromatography (HPLC)
  • Calculation of Rf values
  • Identification of compounds and purity assessment

—

What Is Chromatography?

Chromatography is a separation technique that splits a mixture into its individual components. The name comes from Greek: chroma (colour) and graphia (writing) — literally, “colour writing.”

All chromatographic methods rely on a single principle:

Different substances in a mixture have different affinities for a stationary phase and a mobile phase. These differences in affinity cause the substances to separate.

🔬

Need expert Chemistry tutoring?

I'm Chloe — an Oxford-trained chemist with over 20 years of experience teaching at the UK's top independent schools. I work with a small number of students each year for focused, personalised 1:1 Chemistry tutoring online.

Whether your child is targeting an A*, preparing a Medicine or Oxbridge application, or needs to rebuild their confidence in Chemistry — I'd love to help.

Contact me →

In practical terms: you have two phases — a stationary phase (doesn’t move) and a mobile phase (moves). Compounds in the mixture are carried by the mobile phase. If a compound “likes” (dissolves readily in) the mobile phase, it moves fast. If it “likes” the stationary phase, it moves slowly. This difference in movement rate causes separation.

—

Paper Chromatography

The Apparatus and Method

Stationary phase: Paper (usually cellulose) — it’s polar and has a large surface area with many hydroxyl groups (–OH).

Mobile phase: A solvent (e.g., ethanol, water, or a mixture) — the solvent moves up the paper via capillary action.

Procedure (Standard):

  1. Draw a baseline in pencil (not pen — pen ink will dissolve and interfere) about 1 cm from the bottom of the paper.
  2. Apply a small spot of the mixture on the baseline using a capillary tube. Allow the spot to dry completely.
  3. Repeat (if needed): For better separation, you may apply the spot 2–3 times, allowing it to dry each time. This concentrates the sample.
  4. Place the paper in a chromatography jar containing solvent (to a depth of about 0.5 cm — below the baseline).
  5. Cover the jar with a lid or watch glass to saturate the atmosphere with solvent vapour (prevents evaporation and ensures even solvent distribution).
  6. Allow the solvent front to rise nearly to the top of the paper (but not off the paper).
  7. Remove the paper and immediately mark the solvent front in pencil before it evaporates.
  8. Allow the paper to dry.
  9. Identify the spots: Using a locating agent (see below) if the compounds aren’t coloured.

Key Principle: Separation Based on Polarity

Polar compounds interact strongly with the polar paper (hydrogen bonding with –OH groups). They move slowly up the paper — they spend more time on the stationary phase.

Non-polar (or weakly polar) compounds interact weakly with the paper but dissolve readily in the organic solvent (mobile phase). They move quickly up the paper.

The mobile phase choice matters.** Using a more polar solvent favours faster movement for all compounds. Using a less polar solvent slows down everything but has a bigger differentiating effect between polar and non-polar compounds.

Plant Pigments — A Classical Example

Plant leaves contain four main photosynthetic pigments:

  • Chlorophyll a (blue-green, most abundant) — polar, hence slower Rf
  • Chlorophyll b (yellow-green) — slightly more polar than chlorophyll a, so slower
  • Xanthophyll (yellow) — less polar, intermediate Rf
  • Carotene (orange-yellow, least polar) — fastest movement, highest Rf

When separated by paper chromatography using a non-polar mobile phase (e.g., petroleum ether), the order from bottom to top is:

Baseline → Chlorophyll a → Chlorophyll b → Xanthophyll → Carotene → Solvent front

Why photosynthesis works: Each pigment absorbs light at slightly different wavelengths. By having a mixture, plants can capture more of the visible light spectrum.

Amino Acids — Another Application

Amino acids are zwitterions (have both positive and negative charges) and are highly polar. On paper chromatography, they don’t have colour, so a locating agent is needed after separation.

Common locating agent: Ninhydrin

Ninhydrin reacts with the –NH2 group of amino acids, producing a purple/blue complex. You spray the dried paper with ninhydrin solution and heat gently. Purple spots appear where amino acids are.

Different amino acids have different Rf values because they have different side chains (–R) with different polarities. This allows identification.

Food Dyes — Quality Control Example

Commercial food dyes are often mixtures of simpler dye molecules. Paper chromatography can reveal the true composition. For instance, a red food colouring might be a mixture of red dye and yellow dye.

Locating agent not needed because dyes are already coloured.

Calculating Rf Values

Rf = (distance travelled by the compound) / (distance travelled by the solvent front)

Or more precisely:

Rf = (distance from baseline to the centre of the spot) / (distance from baseline to the solvent front)

Important: Rf is dimensionless (it’s a ratio). Its value ranges from 0 to 1.

  • Rf = 0 → compound didn’t move (stuck strongly to the stationary phase)
  • Rf = 1 → compound moved with the solvent front (no affinity for stationary phase)
  • 0 < Rf < 1 → normal situation

Why Rf matters for identification: For a given mobile phase and stationary phase (paper), each compound has a characteristic Rf value. By comparing the Rf of an unknown to known standards, you can identify unknown compounds.

Examiners’ note: Always ensure the baseline and solvent front are clearly marked in pencil. If you forget to mark the solvent front immediately, it evaporates, and you can’t calculate Rf. This is a common source of lost marks.

Chromatography paper showing spots and measurements for Rf calculations

—

Thin-Layer Chromatography (TLC)

What’s the Difference?

TLC is similar to paper chromatography but faster and generally gives sharper separation.

Stationary phase: A thin layer of silica gel (SiO2) or alumina (Al2O3) coated on a glass, plastic, or aluminium support (TLC plate).

Mobile phase: A solvent, same as paper chromatography.

Method:

  1. Draw a baseline in pencil about 1 cm from the bottom of the TLC plate.
  2. Apply a small spot of the mixture on the baseline (using a capillary tube).
  3. Allow to dry completely.
  4. Place the plate vertically in a chromatography jar containing solvent (to a depth just below the baseline).
  5. Cover the jar (as with paper chromatography).
  6. Allow the solvent front to rise to near the top.
  7. Remove the plate and immediately mark the solvent front in pencil.
  8. Dry the plate.
  9. Visualise the spots: Unlike coloured compounds, many organic molecules don’t have colour. Use a UV lamp (366 nm or 254 nm) — many organic compounds fluoresce or absorb UV light. Compounds appear as dark spots against a bright background.

Why TLC Is Better Than Paper:

  • Faster: Silica gel particles are smaller and more uniform than paper fibres, so solvent travels faster. A separation that takes 30 minutes on paper might take 5 minutes on TLC.
  • Better resolution: Sharper spots, less diffusion, better separation of similar compounds.
  • More versatile stationary phases: Silica gel is more polar than cellulose; alumina is even more polar. This allows you to optimise separation by choosing the right stationary phase.
  • Better for non-polar compounds: Paper chromatography relies on the paper’s hydroxyl groups for polarity. TLC with silica gel works better for a wider range of compounds, including very non-polar organic molecules.

Locating Agents for TLC:

  • UV light (254 nm or 366 nm): Many organic compounds have conjugated systems that absorb or fluoresce under UV. The most common for exam purposes.
  • Iodine vapour: Iodine reacts with organic compounds, forming brown/dark complexes. Good for non-polar compounds like lipids and hydrocarbons.
  • Ninhydrin: Same as paper chromatography — for amino acids.
  • 2,4-DNP (2,4-dinitrophenylhydrazine): Forms orange/red complexes with carbonyl compounds (aldehydes and ketones).

—

Gas Chromatography (GC) and Gas Chromatography-Mass Spectrometry (GC-MS)

The Key Difference: Volatile Compounds

GC is used for volatile organic compounds (those that vaporise easily). It’s not for paper or TLC anymore — the stationary phase is a liquid or polymer coated inside a long, thin metal capillary tube, and the mobile phase is an inert gas (helium, nitrogen, or hydrogen).

Basic Process:

  1. Inject the sample (a few microliters of liquid or solution) into a heated injector port.
  2. The sample vaporises immediately (the injector is typically 200–300°C).
  3. The vaporised sample is carried by the inert gas (mobile phase) through the capillary column.
  4. The column is temperature-programmed (starts at a moderate temperature, then heats gradually). As it heats, compounds with lower boiling points vaporise and move through faster; compounds with higher boiling points condense slightly and move slower.
  5. Compounds exit the column at different times — this is called the retention time (tR).
  6. A detector (usually a flame ionisation detector, FID) detects each compound as it exits, producing a chromatogram — a plot of signal intensity vs. time.

Reading a GC Chromatogram:

The x-axis is time (in minutes), and the y-axis is signal intensity (in arbitrary units).

Each peak represents one compound. The area under a peak is proportional to the amount (moles) of that compound.

Examiners’ note: Don’t confuse retention time with polarity (as in paper/TLC). In GC, retention time depends on boiling point and interaction with the column stationary phase. A more polar compound might be retained longer if it binds strongly to a polar stationary phase, but if the column is non-polar, a less polar compound might be retained longer.

Advantages of GC:

  • Very high resolution: Can separate compounds with very similar properties.
  • Quantitative: Peak area is proportional to the amount of compound.
  • Fast: A complete separation might take 10–20 minutes.
  • Requires only tiny samples (microliters).

Limitations of GC:

  • Only for volatile compounds: Large molecules, proteins, and polymers can’t be analysed by GC.
  • Can cause thermal decomposition: If a sample isn’t thermally stable, it might break apart in the heated injector or column, giving misleading results.
  • Identification is not straightforward: You know the retention time, but that alone doesn’t identify the compound. You need standards for comparison.

GC-MS — Adding Identification Power

A mass spectrometer (MS) can be attached to the outlet of a GC column. As compounds exit the column and enter the MS, they’re ionised and fragmented. The m/z ratio (mass-to-charge ratio) of each fragment is measured.

Each compound produces a characteristic fragmentation pattern called a mass spectrum.

This fragmentation pattern is like a fingerprint — you can compare it to a database and identify the compound with high confidence.

In exam context: You might be given a GC-MS result showing:

  • A retention time (tells you something about volatility and polarity)
  • A mass spectrum (fragments and their m/z ratios)

The molecular ion peak (M+) in the mass spectrum gives the molecular mass, which narrows down the possibilities. The fragmentation pattern then confirms the identity.

—

High-Performance Liquid Chromatography (HPLC)

Where HPLC Fits:

HPLC is used for non-volatile compounds — molecules that break down or decompose if heated, or are simply too large/polar to vaporise.

Examples: pharmaceuticals, amino acids in solution, dyes, pigments, proteins (to some extent).

Key Features:

  • Stationary phase: A fine powder (silica gel, polymers, etc.) packed into a steel column.
  • Mobile phase: A liquid solvent (or mixture of solvents) pumped through the column at high pressure (100–400 atm), hence the name “high-performance.”
  • Detector: Often a UV detector or refractive index detector, detecting compounds as they exit.

Separation Mechanism:

Similar to TLC — compounds with a stronger affinity for the stationary phase move slowly; those that dissolve readily in the mobile phase move fast. By adjusting the mobile phase composition (polarity), you can fine-tune separation.

Advantages:

  • Works for non-volatile and heat-sensitive compounds.
  • Very high resolution and sensitivity.
  • Quantitative: Peak area proportional to analyte amount.
  • Automated: Can run many samples without manual intervention.

In Exam Context:

HPLC is less commonly examined in detail than GC or paper/TLC, but you should know:

  • It’s used for polar, involatile, or heat-sensitive compounds.
  • The principle (affinity for stationary/mobile phase) is the same as TLC, just at higher pressure and with a liquid mobile phase.
  • A chromatogram (signal vs. time) is produced, with each peak representing one compound.

—

Comparing Chromatographic Methods

Method Stationary Phase Mobile Phase Best For Speed Quantitative?
Paper Cellulose (polar) Solvent (organic or aqueous) Polar compounds, dyes, amino acids 30 min – 1 hour Qualitative mainly
TLC Silica gel (polar) or alumina Solvent (organic or aqueous) Organic molecules, lipids, pigments 5–20 min Semi-quantitative (via spot size)
GC Polymer (liquid coating) inside capillary Inert gas (He, N2, H2) Volatile organic compounds 10–30 min Highly quantitative
GC-MS As GC As GC Volatile compounds (identification + quantification) As GC Yes, with structural info
HPLC Silica gel or polymers Liquid (aqueous, organic, or mixed) Non-volatile, polar, heat-sensitive compounds 10–30 min Highly quantitative

—

Common Exam Questions — And How to Answer Them

Q: “Why is a baseline drawn in pencil, not pen?”

Answer: Pencil is insoluble in the solvent and won’t dissolve or interfere with the separation. Pen ink contains organic dyes that dissolve in the mobile phase and would contaminate the sample mixture, creating additional spots and obscuring results.

Q: “Why must the solvent level be below the baseline?”

Answer: If the solvent level is above the baseline, the sample will dissolve directly into the solvent (without being on the stationary phase), defeating the purpose of separation. The baseline must be above the solvent line so that the sample is on the paper/TLC plate when the solvent rises.

Q: “Why is the chromatography jar covered?”

Answer: The cover (lid or watch glass) traps the solvent vapour, saturating the atmosphere inside the jar. This prevents the solvent from evaporating rapidly from the paper/plate, ensures even solvent distribution, and prevents the edges of the paper from drying out (which would distort the separation).

Q: “A student forgot to mark the solvent front. Can the experiment still be analysed?”

Answer: No. Without knowing how far the solvent front travelled, you can’t calculate Rf values or identify the compounds. Always mark the solvent front immediately upon removing the paper from the jar, before it evaporates.

Q: “How would you identify an unknown amino acid if it has the same Rf as two known amino acids?”

Answer: Use a different solvent (mobile phase). The Rf value depends on the solvent. A different solvent might give different Rf values for the two amino acids, allowing you to distinguish them. Alternatively, use a different locating agent or combine two solvents in a different ratio (2D chromatography).

Q: “Why does GC require volatile compounds?”

Answer: In GC, the sample is vaporised in the hot injector and must remain in the gas phase throughout the column. Non-volatile (high-boiling point) compounds would condense inside the column, blocking it or giving tailing peaks. HPLC is used for non-volatile compounds because the mobile phase is a liquid.

—

Purity Assessment

Chromatography can assess compound purity:

  • One spot only: The compound is pure (or at least, any impurities have the same Rf).
  • Multiple spots: The compound is impure; each spot is a different compound.
  • Spot size and shape: A large, diffuse spot might indicate impurity or decomposition. A sharp, well-defined spot suggests purity.

In GC: One peak = pure (or one major component). Multiple peaks = mixture.

—

Key Points to Memorise for OCR Exams

  • Rf = distance of compound / distance of solvent front. Rf is constant for a given compound, solvent, and stationary phase.
  • Polar stationary phase + polar solvent = slow movement of polar compounds.
  • Non-polar stationary phase + non-polar solvent = slow movement of non-polar compounds.
  • Paper chromatography: baseline in pencil, mark solvent front immediately, cover jar to saturate solvent vapour.
  • TLC: faster and sharper than paper, uses UV light for colourless compounds.
  • GC: for volatile compounds, retention time depends on boiling point and affinity for column phase.
  • GC-MS: combines GC separation with MS identification; fragmentation pattern is compound-specific.
  • HPLC: for non-volatile, heat-sensitive compounds, uses liquid mobile phase at high pressure.

—

End of OCR A 6.3.1 notes