A Level Chemistry Notes, Chemistry A Level

Edexcel Topic 14: Redox II – A Level Chemistry Complete Notes

Edexcel Topic 14: Redox II – A Level Chemistry Complete Notes

Redox chemistry revision notes with periodic table and electron transfer diagrams

Introduction to Redox II

Topic 14 builds on your foundational redox understanding from Topic 13. Here, we focus on electrode potentials, electrochemical cells, predicting spontaneity, and non-spontaneous processes (electrolysis).

This is the topic that separates A* students from the rest. Examiners love electrode potential calculations. You need to be able to:

  • Calculate cell potentials using E° values
  • Predict if a reaction will happen spontaneously
  • Explain electrochemical cells in terms of electron flow and ion movement
  • Apply Faraday’s laws to electrolysis calculations

14.1 – Electrode Potentials and Electrochemical Cells

What Is an Electrode Potential?

The standard electrode potential (E°) is the voltage (potential difference) generated when a half-cell is connected to the standard hydrogen electrode (SHE) under standard conditions:

🔬

Need expert Chemistry tutoring?

I'm Chloe — an Oxford-trained chemist with over 20 years of experience teaching at the UK's top independent schools. I work with a small number of students each year for focused, personalised 1:1 Chemistry tutoring online.

Whether your child is targeting an A*, preparing a Medicine or Oxbridge application, or needs to rebuild their confidence in Chemistry — I'd love to help.

Contact me →
  • Temperature: 25°C (298 K)
  • Pressure: 1 atm (101 kPa)
  • Concentration: 1 mol dm–3 for ions in solution

The hydrogen electrode is defined as E° = 0 V (by definition).

Half-reaction at SHE: 2H+(aq) + 2e– → H2(g)

Understanding the Sign Convention

Positive E° means the half-reaction is more easily reduced than hydrogen.

Negative E° means the half-reaction is less easily reduced than hydrogen (or more easily oxidised).

Example:

  • Cu2+ + 2e– → Cu — E° = +0.34 V (copper ions are easily reduced; Cu is a good oxidising agent)
  • Zn2+ + 2e– → Zn — E° = –0.76 V (zinc ions are harder to reduce; Zn is a poor oxidising agent but good reducing agent)

Electrochemical Cells – Galvanic (Voltaic) Cells

A galvanic cell is a device that uses spontaneous redox reactions to generate electrical current.

The Zn-Cu Cell (Daniell Cell):

Two half-cells connected by a wire and salt bridge:

  • Anode (negative electrode): Zn electrode in ZnSO4 solution — Zn is oxidised (loses electrons)
  • Cathode (positive electrode): Cu electrode in CuSO4 solution — Cu2+ is reduced (gains electrons)
  • Wire: Electrons flow from anode (Zn) through the wire to cathode (Cu)
  • Salt bridge: Allows ions to flow to maintain charge balance

Half-reactions:

  • Oxidation (anode): Zn → Zn2+ + 2e–
  • Reduction (cathode): Cu2+ + 2e– → Cu
  • Overall: Zn + Cu2+ → Zn2+ + Cu
Galvanic cell diagram showing anode cathode salt bridge and electron flow

Calculating Cell Potential

Formula:

E°cell = E°cathode – E°anode

Or equivalently:

E°cell = E°reduction – E°oxidation

Example: Zn-Cu cell

E°cell = E°(Cu2+/Cu) – E°(Zn2+/Zn)

E°cell = (+0.34) – (–0.76) = +1.10 V

Interpretation: The positive value tells us this reaction is spontaneous (happens on its own).

Rules for Spontaneity

  • E°cell > 0: Reaction is spontaneous (forward reaction occurs)
  • E°cell < 0: Reaction is non-spontaneous (reverse reaction occurs)
  • E°cell = 0: System is at equilibrium

14.2 – Using Electrode Potential Data to Predict Reactions

The Rule: Stronger Oxidising Agent Wins

When two half-reactions are mixed:

  • The substance with the more positive E° will be reduced (it is the stronger oxidising agent)
  • The substance with the more negative E° will be oxidised (it is the stronger reducing agent)

Example: Will Fe3+ oxidise Cu to Cu2+?

  • Fe3+ + e– → Fe2+ — E° = +0.77 V
  • Cu2+ + 2e– → Cu — E° = +0.34 V

Fe3+ has the more positive potential, so it will be reduced (Fe3+ acts as the oxidising agent).

E°cell = 0.77 – 0.34 = +0.43 V

Yes, this reaction is spontaneous.

Predicting Which Half-Reaction Occurs

At the cathode (reduction): The ion with the most positive E° will be preferentially reduced.

At the anode (oxidation): The species with the least positive E° (most negative) will be preferentially oxidised.

Example: Electrolyzing CuSO4 with copper electrodes

Possible cathode reactions:

  • Cu2+ + 2e– → Cu — E° = +0.34 V
  • 2H+ + 2e– → H2 — E° = 0.00 V

Cu2+ has the more positive potential, so Cu2+ is reduced at the cathode.

Possible anode reactions:

  • Cu → Cu2+ + 2e– — E° = –0.34 V (oxidation of Cu metal)
  • 2H2O → O2 + 4H+ + 4e– — E° ≈ –0.82 V

Cu has the less negative potential (more positive), so Cu metal is oxidised at the anode (it dissolves).

14.3 – Factors Affecting Electrode Potential

Standard electrode potentials assume standard conditions. In reality:

Concentration (Nernst Equation — Not Required for A Level, But Good to Know)

If you increase the concentration of the species being reduced, you make that half-cell more positive (more likely to reduce). If you decrease it, the half-cell becomes more negative.

Practical effect: A cell’s EMF (electromotive force) decreases as the cell operates because reactant concentrations decrease and product concentrations increase.

Temperature

Electrode potentials change slightly with temperature (given in the data booklet when needed).

Pressure (for gas reactions)

Higher pressure favours the forward reaction (Le Chatelier).

14.4 – Electrolysis

What Is Electrolysis?

Electrolysis is the non-spontaneous decomposition of an ionic compound using electrical current.

E°cell < 0, so we must supply energy (voltage) to make it happen.

Terminology

  • Anode: Positive electrode (oxidation occurs)
  • Cathode: Negative electrode (reduction occurs)
  • Electrolyte: Ionic substance (molten or aqueous) that conducts electricity
  • Electrode: The conductor (often inert: carbon, platinum; or reactive: copper)

Memory trick: OIL RIG – Oxidation Is at the anode (L), Reduction at the Is at the cathode (G)

Electrolysis of Molten Compounds

Example: Molten NaCl

Anode (oxidation): 2Cl– → Cl2 + 2e–

Cathode (reduction): Na+ + e– → Na

Overall: 2NaCl → 2Na + Cl2

Key point: In molten solutions, there’s only one cation and one anion, so the products are straightforward.

Electrolysis of Aqueous Solutions

More complex because water itself can be oxidised or reduced.

Standard reduction potentials in water:

  • 2H+ + 2e– → H2 — E° = 0.00 V
  • O2 + 4H+ + 4e– → 2H2O — E° = +1.23 V

At the cathode: The ion with the most positive E° is reduced. Usually:

  • If the metal has E° > –2 V (rough guideline), the metal ion is reduced (Mn+ + ne– → M)
  • If E° < –2 V, water is reduced instead (2H+ + 2e– → H2)

At the anode: The ion with the most negative (least positive) E° is oxidised. Usually:

  • Halide ions (Cl–, Br–, I–) are oxidised easily (they have negative E° values)
  • OH– (or water) is oxidised instead (2H2O → O2 + 4H+ + 4e–)
  • SO42–, NO3– are very hard to oxidise, so water is oxidised instead

Example: Electrolysis of CuSO4 solution with inert (carbon) electrodes

Cathode: Cu2+ + 2e– → Cu (Cu2+ is easier to reduce than H+)

Anode: 2H2O → O2 + 4H+ + 4e– (SO42– is too hard to oxidise)

Overall: 2CuSO4 + 2H2O → 2Cu + O2 + 2H2SO4

Faraday’s Laws of Electrolysis

First Law: The amount of substance discharged is directly proportional to the charge passed.

Second Law: For a fixed amount of charge, the mass of substance discharged is proportional to its molar mass and inversely proportional to the number of electrons transferred.

Practical formula:

Q = I × t (Charge = Current × Time, in Coulombs)

n = Q ÷ F (Moles = Charge ÷ Faraday constant)

where F = 96,500 C mol–1 (approximately 96,000)

Example: How many grams of copper are deposited when a current of 2 A flows through a CuSO4 solution for 30 minutes?

Time = 30 min = 1,800 s

Charge Q = I × t = 2 × 1,800 = 3,600 C

Moles of electrons = Q ÷ F = 3,600 ÷ 96,500 = 0.0373 mol e–

From the half-reaction: Cu2+ + 2e– → Cu, 2 moles of electrons produce 1 mole of Cu

Moles of Cu = 0.0373 ÷ 2 = 0.01865 mol

Mass of Cu = 0.01865 × 64 = 1.19 g

14.5 – Applications of Electrochemistry

Industrial Applications

  • Extraction of reactive metals: Electrolysis of molten ores (e.g., aluminium from Al2O3)
  • Refining of metals: Electrolysis of copper to purify it
  • Production of chemicals: Chlor-alkali process (Cl2, NaOH from NaCl)
  • Electroplating: Coating one metal with another (e.g., plating steel with zinc for corrosion resistance)

Electroplating Example

To gold-plate a ring:

  • Cathode: The ring (object being plated)
  • Anode: A block of pure gold
  • Electrolyte: Gold chloride solution (contains Au3+)
  • Process: Au3+ ions are reduced and deposit on the ring; gold at the anode dissolves

Key Formulae to Memorise

E°cell = E°cathode – E°anode

E°cell > 0 → Spontaneous

Q = I × t

n = Q ÷ F (where F = 96,500 C mol–1)

Common Exam Mistakes to Avoid

  • Mixing up anode and cathode: Remember OIL RIG. Anode = oxidation = losing electrons.
  • Getting the sign of E° backwards: More positive = easier to reduce = better oxidising agent.
  • Forgetting to balance electrons: When combining half-reactions, multiply so electrons match.
  • Using E° values upside down: Always subtract the oxidation half from the reduction half.
  • Forgetting to consider water in aqueous electrolysis: Water can be oxidised or reduced.
  • Calculation errors in Faraday problems: Pay careful attention to unit conversions (minutes to seconds, etc.).

Summary

Topic 14 is about predicting redox behaviour using electrode potentials. Master the sign convention, the calculation of cell potential, and Faraday’s laws. Understand why some ions are oxidised while others are reduced in aqueous electrolysis. Practice past paper questions – this is the topic examiners love.

Leave a Reply